| Place of Origin: | China | 
|---|---|
| Brand Name: | Desun Uniwill | 
| Certification: | CE | 
| Model Number: | DS-380 | 
| Minimum Order Quantity: | 0~100 pcs | 
| Price: | $280.00 - $400.00/ Piece | 
| Packaging Details: | Carton packaging | 
| Delivery Time: | 7~ 15 working days | 
| Payment Terms: | L/C, D/A, D/P, T/T | 
| Supply Ability: | 0~1000 pcs | 
| Model: | DS380 | Principle: | Fluorescence Analysis Method | 
|---|---|---|---|
| Measuring Range: | 0~20mg/L | Response Time: | 3 Seconds | 
| Accuracy: | 1% | Protection Level: | IP68 | 
| Installation: | Submersible | Temperature Sensor: | NTC | 
| Temperature Range: | 0~50°C | Temperature Accuracy: | ±0.2°C | 
| Output: | Support RS-485, MODBUS Protocol | Power Supply: | DC 6~12V, Current <50mA | 
| Size: | Φ26*155 Mm | Probe Cable Length: | Default 5 M | 
| Fluorescent Cap Life: | 1 Year | Maximum Working Pressure: | 3bar | 
| Housing Material: | SS316/Titanium Alloy | ||
| Highlight: | Aquaculture Digital DO Sensor,Dissolved Oxygen Sensor Analyzer,RS485 Optical Water Oxygen Sensor | ||
Desun Uniwill fluorescent dissolved oxygen sensors use a new generation of fluorescence lifetime technology and high performance fluorescent materials. No oxygen consumption,No flow rate limitation, no electrolyte, no maintenance and calibration,no interference from hydrogen sulfide, excellent stability. Built-in temperature sensor, automatic temperature compensation. RS485 output, can be networked without a controller.
Technical Specifications
| Item | Parameters | 
| Model | DS380 | 
| Principle | Fluorescence analysis method | 
| Measuring range | 0~20mg/L or 0-200% saturation | 
| Response time | 3 sec | 
| Accuracy | 1% | 
| Protection level | IP68 | 
| Installation | Submersible | 
| Temperature sensor | NTC | 
| Temperature range | 0~50°C | 
| Temperature accuracy | ±0.2°C | 
| Output | Support RS-485, MODBUS protocol | 
| Power supply | DC 6~12V, current <50mA | 
| Size | Φ26*155 mm | 
| Probe cable length | Default 5 m, customized 10m, 15 m and 30 m cable | 
| Fluorescent cap life | 1 year | 
| Maximum working pressure | 3bar | 
| Housing material | SS316/Titanium alloy | 
Sensor maintenance
1) Sensor outer surface:
Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.
2) The outer surface of the fluorescent cap:
Remove the protective cover at the front end of the sensor, rinse the dirt on the sensor window with clean water, and finally cover the cover; if you need to wipe, use a soft cloth and carefully wipe the force direction.
Dimensions:

Photos